Pontificia Universidad Católica de Chile Pontificia Universidad Católica de Chile
Correia T., Ginami G., Rashid I., Nordio G., Hajhosseiny R., Ismail T., Neji R., Botnar C., Prieto C. (2021)

Accelerated High-resolution Free-breathing 3D whole-heart T2-prepared Black-blood and Bright-blood Cardiac MRI

Revista : Journal of Cardiovascular Magnetic Resonance
Volumen : 22
Número : 88
Tipo de publicación : ISI Ir a publicación

Abstract

BackgroundThe free-breathing 3D whole-heart T2-prepared Bright-blood and black-blOOd phase SensiTive inversion recovery (BOOST) cardiovascular magnetic resonance (CMR) sequence was recently proposed for simultaneous bright-blood coronary CMR angiography and black-blood late gadolinium enhancement (LGE) imaging. This sequence enables simultaneous visualization of cardiac anatomy, coronary arteries and fibrosis. However, high-resolution (<?1.4?×?1.4?×?1.4 mm3) fully-sampled BOOST requires long acquisition times of?~?20 min.MethodsIn this work, we propose to extend a highly efficient respiratory-resolved motion-corrected reconstruction framework (XD-ORCCA) to T2-prepared BOOST to enable high-resolution 3D whole-heart coronary CMR angiography and black-blood LGE in a clinically feasible scan time. Twelve healthy subjects were imaged without contrast injection (pre-contrast BOOST) and 10 patients with suspected cardiovascular disease were imaged after contrast injection (post-contrast BOOST). A quantitative analysis software was used to compare accelerated pre-contrast BOOST against the fully-sampled counterpart (vessel sharpness and length of the left and right coronary arteries). Moreover, three cardiologists performed diagnostic image quality scoring for clinical 2D LGE and both bright- and black-blood 3D BOOST imaging using a 4-point scale (1–4, non-diagnostic–fully diagnostic). A two one-sided test of equivalence (TOST) was performed to compare the pre-contrast BOOST images. Nonparametric TOST was performed to compare post-contrast BOOST image quality scores.ResultsThe proposed method produces images from 3.8?×?accelerated non-contrast-enhanced BOOST acquisitions with comparable vessel length and sharpness to those obtained from fully- sampled scans in healthy subjects. Moreover, in terms of visual grading, the 3D BOOST LGE datasets (median 4) and the clinical 2D counterpart (median 3.5) were found to be statistically equivalent (p??3.5).ConclusionsThe proposed framework provides high?resolution 3D whole-heart BOOST images from a single free-breathing acquisition in?~?7 min.